- Help Center
- 06. Web App Reports
- Occupancy Reports
-
01. Getting Started with Lumos Controls
-
02. Commission & Configure the Devices
- Settings before Device Commissioning (Pre-Commissioning)
- Control Devices- Commission
- Control Devices- Configure Output Channel Settings
- Control Devices- Configure Light Configuration Settings
- Control Devices- Configure Device Power Settings
- Control Devices- Configure Device Configuration Settings
- Control Devices- Configure Input Sensor Settings
- Sensors- Commission & Configure
- Switches- Commission & Configure
- Gateway- Commission & Configure
- Repeater- Commission & Configure
- Beacon Settings
- FAQ
-
03. Mobile App Features
-
04. Automate Lighting Experience
- Scene Schedule
- Motion Based Automation- Using Wireless Sensor
- Motion Based Automation- Using Wired Sensor
- Daylight Harvesting
- Daylight Harvesting using Open Loop mode
- Daylight Harvesting using Closed Loop mode
- Daylight Harvesting using Custom mode
- Automated Demand Response
- Human Centric Lighting
- FAQ
-
05. Web App Features
-
06. Web App Reports
-
Emergency Lighting
-
BMS Integration
-
Troubleshooting Guide
-
FAQ
-
Technical Data Sheets & Installation Guides
- Controller- Radiar D10
- Controller- ARD32
- Controller- ARD4
- Controller- AFD1/4
- Controller- AF10
- Controller- AR10
- Controller- Omni TED
- Driver- Ldrive 32W
- Driver- Ldrive 36W
- Driver- Ldrive 42W
- Driver- Ldrive 60W
- Sensor- Cyrus C
- Sensor- Cyrus F
- Sensor- Cyrus AP
- Sensor- Cyrus AM
- Switch- Catron IV
- Switch- Catron V
- Switch- Catron AI
- Gateway- Enor U
- Gateway- Enor E
- Repeater- Senor E
- Others- WIM2480
- Others- LED Flat Panels
- Others- Retrofit Troffers
- Warranty Docs
-
Release Notes
-
Other Articles
Data displayed in the Occupancy - Trend Report
Occupancy trend reports display the occupancy trend for a building/ floor/zone/group/device over the chosen day/week/month. By default, the occupancy graph of the entire building shall be displayed, and filters are available to view data at a -
- Floor Level
- Zone Level
- Group Level
- Sensor Level
The graph shall display the occupancy data on
- an hourly basis if viewed for a particular day
- a daily basis if viewed for a particular week
- a daily basis if viewed for a particular month
- 5 Minutes for daily report
- 2 Hours for weekly and monthly reports (represented on a daily basis)
You can also visit the following sections for more information:
To know about the data displayed in the Occupancy - Analytics report, click here
To know the purpose of Energy Consumption Reports, click here